( Brand: Burleigh ), ( Manufacturer Part Number: WA-2500 ), ( Model: WAVEMETER ), ( Part Type: Laser )
The Wa-2500 Burleigh Wavemeter is a state-of-the-art tunable laser sapphire dye system, designed for precision frequency and wavelength measurement applications. This advanced instrument is equipped with a high-quality sapphire dye laser, which provides stable and accurate output over a wide wavelength range, from 1900 to 2500 nanometers.
The Wa-2500 features a user-friendly interface, allowing for easy operation and data analysis. Its digital phase lock loop (DPLL) technology ensures high precision and stability, with a frequency stability of less than 10 Hz and a wavelength stability of less than 0.005 nm. The instrument also includes a built-in interferometer, which allows for absolute frequency and wavelength measurements, as well as a fast frequency sweep function, which enables quick and accurate scanning of a broad spectral range.
The Wa-2500 is built with high-quality components, including a robust sapphire dye cell and a precision-machined optical bench. Its compact and rugged design makes it suitable for use in a variety of environments, from laboratory settings to field applications. Additionally, the instrument is equipped with a built-in temperature control system, which helps to maintain the stability of the dye laser and improve the overall performance of the wavemeter.
Overall, the Wa-2500 Burleigh Wavemeter is a powerful and versatile tool for frequency and wavelength measurement applications. Its high-quality components, user-friendly interface, and advanced technology make it an ideal choice for researchers and engineers working in fields such as laser physics, optical communications, and spectroscopy.
Pros of buying a WA-2500 Burleigh Wavemeter:1. High precision: The WA-2500 Burleigh wavemeter is known for its high precision, with an absolute frequency stability of less than 1 part in 10 11. This makes it ideal for applications that require accurate measurement of optical frequencies.
2. Tunable laser source: The WA-2500 Burleigh wavemeter uses a tunable laser source, which allows for a wide range of wavelengths to be measured. This makes it a versatile instrument for various applications in the field of optics and photonics.
3. Sapphire dye: The use of sapphire dye as the gain medium in the tunable laser source ensures long-term stability and reliability. Sapphire is a high-quality material that is resistant to thermal and mechanical stress, which makes it suitable for use in a wavemeter.
4. High measurement speed: The WA-2500 Burleigh wavemeter can measure optical frequencies at a high speed, making it an efficient instrument for high-throughput applications.
Cons of buying a WA-2500 Burleigh Wavemeter:1. High cost: The WA-2500 Burleigh wavemeter is a high-end instrument and comes with a correspondingly high price tag. The cost may be prohibitive for some users, especially for those with limited budgets.
2. Complex operation: The WA-2500 Burleigh wavemeter requires specialized knowledge and expertise to operate and maintain. This may be a challenge for users who are not familiar with wavemeters or optical instrumentation.
3. Requires a stable environment: The WA-2500 Burleigh wavemeter requires a stable environment to operate effectively. Any vibrations, temperature changes, or electrical noise can affect its performance and accuracy.
In conclusion, the WA-2500 Burleigh wavemeter is a high-precision and versatile instrument that is suitable for various applications in the field of optics and photonics. Its use of a tunable laser source, sapphire dye, and high measurement speed make it an efficient and reliable instrument. However, its high cost and complexity of operation may be a challenge for some users. If the benefits of the WA-2500 Burleigh wavemeter outweigh its drawbacks for a particular application, it can be a worthwhile investment. Recommendation: If you require high-precision measurement of optical frequencies and have the budget and expertise to operate and maintain the WA-2500 Burleigh wavemeter, then it can be a valuable addition to your laboratory or research facility.
Clean, used Burleigh WA-2500 Wavemeter jr. We'll offer a 30 day performance warranty on this.
A Wavemeter uses scanning Michelson interfered to measure the wave length of cw laser sources. With accessories. Key specifications: wave length range: 400 - 1800nm accuracy: 1 part in 10,000 display resolution.
FCC fiber coupled beam receiver with the kinematic mount shown 1m single mode patch cable power cord 3 NBC cables you can use to connect back panel outputs an oscilloscope lasers and were used for testing are not included. This unit is quite sensitive.
Swapping the detector is a 5 minute job and well described in users manual. 8nm that a small Heine laser can be used for calibration as shown in our pictures the back panel outputs with an oscilloscope to get idea of line width your.
This is in good shape and i've tested it found excellent working condition. I'm happy to reconfigure with the VI's detector if you're working a dye or diode lasers in visible 400-1100nm wave length s. The VI's detector is used for lasers operating from 400 to 1100 nanometers, and Ir that operate 600 1800 nanometers.
Items listed as new or used are guaranteed to arrive in the condition described listing. Sec in averaging mode fiber connector: FCC ac power: 110 220v here for the WA-2500 user manual. This listing includes: Burleigh WA-2500 Wavemeter jr.
I've left this with the Ir detector installed since that covers ti:sapphire and DMD lasers 600-1800nm. The primary application is measurement of wave length or frequency tunable lasers that operate from 400 to 1800 nanometers, particularly dye lasers, ti:sapphire and diode.
01nm display units: nanometers or wave number in vacuum air update period. It combines accuracy with ease of use. I can get about half scale on the bar-graph using a 1mw Heine laser coupled into single mode fiber and it has no problem detecting 20dbm infrared signal.
Two detectors are provided to cover this range with high sensitivity. Warranty items listed as-is do not include any.
Please before buying if you require a different shipping method. The accuracy is 1 part in 10,000 over full wave length range.